GETTING STARTED

POWERING THE METER

1. Set the S1 dip switches according to Table 2-3.
2. Connect input signal (refer to Section 3.2 for commonly used sensors).
3. Connect the proper voltage to the power screw terminal (TB1). The meter shows the programmed function (default is rAtE mode).

AC Power Detail Table 3-1
Connector
Description
Europe
USA
TB1-1
AC Line Connection
Brown
Black
TB1-2
AC Neutral Connection
  Blue
White
TB1-3
AC Earth Ground Connection
 Green/Yellow
Green

Signal Connector Table 3-2
Connector
Description
TB2-1
Excitation Output (5 V, 8.2 V or 12.4 Vdc)*
TB2-2
Signal Input*
TB2-3
Signal Return
TB2-4
Reset Input (active when tied to TB2-3)
TB2-5
External Gate Input**
TB2-6
Backup Battery (positive connection, use TB2-3 for return)
* Refer to Table 2-3, S1 DIP Switch Positions.
** Normally used in timing applications, not rate applications. Refer to Section 5.2 (Stopwatch in the Totalize Mode) for more information

Electrical Connection for AC Power
Figure 3- 1. Electrical Connection for AC Power

CONNECTING TO COMMONLY USED SENSORS
3-Wire Sensor with Open Collector Output
Figure 3-2
3-Wire Sensor w/NPN Open Collector Output


TTL/5 V CMOS Output
Figure 3-3
TTL/5 V CMOS Output

3-Wire Sensor with PNP Open Collector Output
Figure 3-4
3-Wire Sensor w/PNP Open Collector Output

2-Wire Magnetic Pickup (Low Level Signals)
Figure 3-5
2-Wire Magnetic Pickup
(Low Level Signals)
2-Wire NAMUR Sensor

Figure 3-6. 2-Wire NAMUR Sensor
2-Wire Contact Closure
Figure 3-7. 2-Wire Contact Closure